Warm insulation side
Read more about Polytex
Read more about Miofol
Read more about Alkreflex
Read more about VASTR
Read more about Tyvek
Read more about Taftex
Vapour control membranes

TAFTEX IN-100

TAFTEX® IN-100 is a moisture-repellent, watertight membrane, which consists of two layers of polypropylene.

1,50 x 50 m Article no. 1115010000
1,50 x 30 m Article no. 1115010001 (incl. integrated adhesive strip)

Description

TAFTEX® IN-100 is a moisture-repellent, watertight membrane, which consists of two layers of polypropylene. TAFTEX® IN-100 is used to prevent moist indoor air infiltrating into insulation layers in wall and roof constructions. This helps to avoid condensation, and eventually mould, within the insulation material.

Applications

TAFTEX® IN-100 is used as a vapour control membrane on the warm side of wall and roof constructions. Thanks to its constant moisture-inhibiting properties, TAFTEX® IN-100 is suitable in buildings in climate class 2 and 3, such as homes, offices, schools, etc. TAFTEX® IN-100 protects constructions against moisture and ensures an optimised and airtight insulation.

Processing

TAFTEX® IN-100 should be applied to the warm side of the roof and wall construction. Use staples to attach the membrane to the underlying construction. It must be possible to read the logo from the inside. Keep an extra 100 mm at all horizontal and vertical overlaps. To ensure effective moisture inhibition, we recommend using TAFTEX® Membrane tape to tape over staples, joints and overlaps. Use VAST-R® Butyl tape or Tyvek® FlexWrap tape to make openings and joints wind- and watertight.

Benefits

Watertight

High tensile strength and flexibility against tears

Airtight

Placed faster than regular membranes

Specifications

Weight 100 gr / m²

Fire class F

Water tightness W1

Water vapour resistance Sd ≤ 19 m

Water vapour transmission 0,6 g / m² / day

Tensile strength machine direction 180N / 50 mm

Tensile strength cross direction 180N / 50 mm

Elongation machine direction 80%

Elongation cross direction 80%

Tear resistance machine direction 160N

Tear resistance cross direction 160N

Temprature resistance -40°C / +80°C

Looking for the right membrane?